Browse all practice questions for the Clinical Sonography III Practice Exam. Search by topic, open any question and review its full explanation, then test yourself in the practice quiz.

Clinical Sonography III Practice Exam 2026 – Complete Study Resource course image
More practice questions

These questions are part of the practice quiz. Start practicing

  • The tcPO2 procedure is used to assess what physiological parameter by vasodilation?
  • In the described path, what is the pressure at the venules?
  • Which ABI value indicates ischemic rest pain?
  • In an access graft, the venous lumen diameter threshold used is at least which measurement?
  • What occurs during contraction of the calf muscle pump?
  • During relaxation, which statement describes distal intraluminal pressure?
  • What occurs during the calf muscle pump at rest?
  • If tissue pressure is higher than intravascular pressure, transmural pressure is which state?
  • Penile pressures and waveforms are used to assess what?
  • Which measurements are essential when calculating graft flow volume?
  • In a supine patient, hydrostatic pressures across major body regions tend to be approximately equal.
  • Which vessel is described as having retrograde flow on the transtemporal study?
  • In transtemporal Doppler, which vessel at 60-80 mm depth demonstrates retrograde flow with velocity near 55 cm/s?
  • Which statement correctly differentiates AC coupling from DC coupling?
  • During expiration, which occurs?
  • ABI value indicating abnormal?
  • What graft connects the brachial artery to the cephalic or basilic vein? It can also connect the SFA to the saphenous vein.
  • An abnormal penile/brachial index is defined as which value, indicating vasculogenic impotence?
  • In transorbital Doppler, which vessel at 40-60 mm depth with antegrade flow around 21 cm/s is described?
  • Which best describes the purpose of using oscillation technique during carotid assessment?
  • What does the STOP Protocol refer to in stroke prevention for sickle cell disease?
  • During post-operative assessment of a hemodialysis access graft, which finding is most directly associated with graft thrombosis due to stenosis?
  • Which graft configuration uses a loop to connect a proximal artery to a distal vein?
  • Which statement best describes infection risk with synthetic grafts?
  • Which range defines a marginal penile/brachial index?
  • Which statement about hydrostatic pressure is true?
  • The device that uses an infrared LED and a nearby photosensor to measure blood volume changes by detecting backscattered light is called what?
  • Hydrostatic pressure is defined as pressure arising from the weight of fluid above.
  • Which statement best describes the penile/brachial index used in this evaluation?
  • What size pseudoaneurysm is considered problematic?
  • Follow the outflow vein to the central veins to evaluate for which complication?
  • Which window is used to assess the retromandibular and proximal intracranial ICA?
  • Veins are what kind of system?
  • Which techniques are performed in penile pressure and waveform testing?
  • During relaxation, which describes the hydrostatic pressure column?
  • In transtemporal Doppler assessment, which vessel is typically observed at a depth of 30-60 mm with antegrade flow around 55 cm/s?
  • Which three findings must be present to diagnose graft stenosis?
  • What is the approximate velocity described for the posterior cerebral artery in this data?
  • During transcranial Doppler screening for sickle cell disease, which arteries are typically evaluated, and what is the normal upper limit for the middle cerebral artery velocity?
  • What is the preferred minimum venous lumen diameter for an access graft?
  • Following papaverine injection to induce erection, measurements are obtained for up to how long post-injection?
  • To evaluate the entire graft course for stenosis or access problems, what is the primary purpose of imaging from the graft to the distal vessels?
  • Strain gauge plethysmography measures which specific physical change in the limb?
  • Which acoustic window is used as the primary access to intracranial vessels in transcranial Doppler imaging?
  • During carotid artery assessment, which compression technique is recommended?
  • Blood flows from which pressure to which pressure?
  • Which test assesses collateral hand circulation before fistula creation?
  • Which of the following best describes a component involved in the calf muscle pump?
  • In transtemporal Doppler, which vessel at about 55-65 mm depth presents bidirectional flow with velocity near 55 cm/s?
  • For a fistula in a hemodialysis access, which venous lumen diameter meets the adequacy threshold?
  • Which finding is an indication for duplex assessment of a hemodialysis access graft?
  • Which factor primarily propels blood toward the heart during the calf muscle pump?
  • Which action is part of the compression technique during carotid assessment?
  • Which post-injection PSV value range is considered marginal?
  • In an upper arm PTFE dialysis graft, what is the typical outflow vein?
  • To obtain a graft flow volume, which three steps should be completed?
  • Which sites of the hemodialysis access graft should be Doppler interrogated?
  • Which of the following is a common graft/fistula complication?
  • In transcranial Doppler, the angle of insonification is assumed to be what?
  • In the transorbital approach, which vessels are assessed?
  • In pre-operative arterial evaluation for a hemodialysis access graft, which parameter indicates arterial inflow?
  • What is the flow volume equation used for grafts?
  • What happens to blood in the deep calf veins during contraction?
  • Which of the following is a venous access complication?
  • Which test demonstrates complete vs incomplete palmar arch patency?
  • In the submandibular approach, which vessels are assessed?
  • What is the normal post-injection PSV threshold?
  • What fistula is created by connecting the radial to the cephalic or the ulnar to the basilic? ALSO known for long-term patency
  • How do PTFE dialysis grafts typically appear on ultrasound?
  • What is the normal high thigh index?
  • Strain gauge plethysmography uses a mercury-filled silicone rubber tube with copper electrodes; what physical change does the gauge measure?
  • Which vessels are connected by a PTFE upper arm hemodialysis graft?
  • How long after calibration are PO2 readings noted?
  • Plethysmography measures which parameter in a limb?
  • During cold immersion testing for perfusion assessment, how long should the hand be immersed in cold water?
  • Post-injection, which statement best describes deep dorsal venous flow?
  • Absence of arterial signal with low diastolic component in the segment proximal to the area indicates what?
  • In the described path from the left ventricle to the right atrium, which sequence correctly lists the vascular segments from proximal to distal?
  • Which genetic disorder causes abnormal hemoglobin, leading to red blood cells with a sickle shape?
  • What does a normal exam look like during a pre-op arterial evaluation?
  • What graft flow volume indicates poor dialysis?
  • Collapsed veins illustrate which transmural pressure state?
  • Which plethysmography uses aluminum strip electrodes around the limb, thigh cuffs to inhibit venous flow, and low-level current to measure impedance with four-wire configuration?
  • Four-wire impedance measurement is used in which plethysmography method?
  • What is the normal graft flow volume range?
  • Which value is the highest among standard venous diameter thresholds used in an access graft?
  • A typical transducer frequency used for penile Doppler duplex ultrasound is?
  • Which agents are used for penile pharmacologic induction during testing?
  • In the transforamenal approach, which vessels are assessed?
  • Vasospasm velocity is considered normal if it is below what value?
  • During the calf muscle pump, blood is propelled toward which direction?
  • Veins are described as which?
  • Grafts/fistulas are allowed to mature for how long before use?
  • During inspiration, which of the following occurs?
  • Which change in Doppler flow characteristics corresponds to deterioration of cerebral perfusion leading toward brain death?
  • Volume plethysmography is also known as which of the following?
  • In the described path from the left ventricle to the right atrium, what is the pressure in the right atrium?
  • The term air-plethysmography is an alternative name for which technique?
  • Thoracic outlet syndrome is approximately what percentage neurogenic and vascular?
  • What is the minimum arterial lumen diameter for an access graft?
  • What is the normal range for tcPO2?
  • An abnormal connection between arteries and veins is called what?
  • For a fistula, which venous lumen diameter is considered adequate?
  • In a hemodialysis access graft, the venous lumen diameter should be at least which measurement?
  • What should be noted when performing compression in carotid assessment?
  • Which statement best describes criteria for diagnosing graft stenosis?
  • Which parameter is used to indicate stenosis at a graft site?
  • What term describes the pressure difference between the inside of a vein and the surrounding tissue?
  • Which change in arterial diameter is expected after papaverine injection?
  • Which ultrasound window is used to evaluate the ophthalmic artery?
  • In photoplethysmography, which kind of light is detected by the sensor to quantify blood volume changes?
  • During relaxation, which statement about proximal deep valves is true?
  • Which value represents the highest recommended minimum venous diameter for an access graft?
  • In an upright patient, which location has the highest hydrostatic pressure?
  • In the transtemporal approach, which vessels are assessed?
  • What is the minimum arterial lumen diameter for a hemodialysis access graft?
  • What graft flow volume indicates possible congestive heart failure?
  • What is the Ohm's law formula?
  • What penile/brachial index value defines a normal result?
  • What measurement is used to determine wound healing potential and anticipated amputation level?
  • What is the normal FBI range?
  • During inspiration, which statement about the IVC is true?
  • Which acoustic window provides access to evaluate the intracranial vertebral and basilar arteries?
  • Which parameter increases with arterial inflow after injection?
  • How many stages are described in brain death?
  • Intermittent compression of the brachial plexus causing arm/hand pain, weakness, and paresthesia describes which syndrome?
  • What combination of studies is typically performed in penile pressure and waveform testing?
  • In the oscillation technique, which action is performed?
  • A penile/brachial index below which value is associated with vasculogenic impotence?
  • In transtemporal Doppler, which vessel at 60-70 mm depth shows antegrade flow with about 39 cm/s velocity?
  • Positions used for thoracic outlet syndrome assessment include which set?
  • Where is the most common site for neointimal hyperplasia in a hemodialysis access graft?
  • Which gradient threshold is considered acceptable for inter-arm comparison in pre-op arterial evaluation?
  • In pre-injection duplex imaging, which resistivity pattern is seen in the penile arteries?
  • During thoracic outlet syndrome evaluation, which modality is used to monitor the limb?
  • Which ABI value indicates multi-level disease or long segment occlusion?
  • What should be done after applying compression during carotid assessment?
  • What term refers to involuntary contraction of a blood vessel?
  • What is the velocity described for the internal carotid artery when imaged via the transorbital window?
  • Which multiplicative factor is used in the graft flow volume equation to convert to per-minute units?
  • Which statement is NOT a characteristic of a normal plethysmography waveform?
  • What is the minimum venous lumen diameter for an access graft (not the preferred size)?
  • What PO2 value range is considered poor?
  • In volume plethysmography, volume changes are converted into what kind of signal for recording?
  • Which pattern is observed or noted during the oscillation technique?
  • Which venous lumen size is specifically recommended for a fistula, not a graft?
  • During contraction, which statement about perforator valves is true?
  • In a PTFE upper arm graft, which artery serves as the inflow?
  • What is the approximate velocity described for the middle cerebral artery in this data set?
  • What is the pressure in the left ventricle in the described pathway?
  • Which statement correctly describes the relationship between the venous thresholds for fistulas and grafts?
  • What graft connects the radial artery to the median cubital, basilic or cephalic vein and can be straight or tapered?
  • After cold immersion, how often are waveforms obtained and for how long?
  • Which post-injection PSV value range is considered reduced?
  • What is the first step in transcranial Doppler (TCD) assessment?
  • During carotid artery assessment, how many cardiac cycles should be held during compression?
  • In neurogenic thoracic outlet syndrome, which structure is primarily compressed?
  • Which of the following is NOT a characteristic of abnormal plethysmography waveform?
  • Which venous lumen size is considered adequate specifically for a fistula?
  • Which of the following is a mechanism contributing to venous hemodynamics?
  • If intravascular pressure is higher than the pressure outside the tissue, the transmural pressure is which state?
  • Which test is commonly performed in conjunction with a hemodialysis access graft assessment?
  • Which plethysmography method uses a cuff around a limb that is inflated to create a volume change, which is converted to an analog pressure signal for recording?
  • What is the normal TBI index?
  • The study that uses an adhesive fixation ring on intact skin with electrolyte solution and heats the skin to 44-45°C to cause vasodilation is called what test?
  • What is the minimum arterial lumen diameter for an access graft? (alternative phrasing)
  • What is the approximate velocity described for the terminal internal carotid artery in this data?
  • Which value is a standard threshold used for venous lumen diameter in an access graft?
  • An oxygen challenge should be used if PO2 falls between normal and poor levels. After the challenge, the PO2 should be higher by how much?
  • Impedance plethysmography is primarily used to assess which condition?
  • Which plethysmography method uses backscattered infrared light to detect blood volume changes?
  • In a transorbital Doppler exam, which vessel at 60-80 mm depth with parasellar flow and about 47 cm/s velocity is described?
  • Which scan protocol is used to evaluate a hemodialysis access graft?
  • What does a normal exam look like during a pre-op venous evaluation?
  • What transducer configuration is typically used for TCD?
  • In duplex imaging after injection, which resistivity pattern is observed in the penile arteries?
  • Which ABI value indicates probable claudication?
  • Distended veins are an example of which transmural pressure state?
Subscribe

Get the latest from Examzify

You can unsubscribe at any time. Read our privacy policy